1.
Front Oncol ; 14: 1378449, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660134

RESUMO

Purpose: Create a comprehensive automated solution for pediatric and adult VMAT-CSI including contouring, planning, and plan check to reduce planning time and improve plan quality. Methods: Seventy-seven previously treated CSI patients (age, 2-67 years) were used for creation of an auto-contouring model to segment 25 organs at risk (OARs). The auto-contoured OARs were evaluated using the Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and a qualitative ranking by one physician and one physicist (scale: 1-acceptable, 2-minor edits, 3-major edits). The auto-planning script was developed using the Varian Eclipse Scripting API and tested with 20 patients previously treated with either low-dose VMAT-CSI (12 Gy) or high-dose VMAT-CSI (36 Gy + 18 Gy boost). Clinically relevant metrics, planning time, and blinded physician review were used to evaluate significance of differences between the auto and manual plans. Finally, the plan preparation for treatment and plan check processes were automated to improve efficiency and safety of VMAT-CSI. Results: The auto-contours achieved an average DSC of 0.71 ± 0.15, HD95 of 4.81 ± 4.68, and reviewers' ranking of 1.22 ± 0.39, indicating close to "acceptable-as-is" contours. Compared to the manual CSI plans, the auto-plans for both dose regimens achieved statistically significant reductions in body V50% and Dmean for parotids, submandibular, and thyroid glands. The variance in the dosimetric parameters decreased for the auto-plans as compared to the manual plans indicating better plan consistency. From the blinded review, the auto-plans were marked as equivalent or superior to the manual-plans 88.3% of the time. The required time for the auto-contouring and planning was consistently between 1-2 hours compared to an estimated 5-6 hours for manual contouring and planning. Conclusions: Reductions in contouring and planning time without sacrificing plan quality were obtained using the developed auto-planning process. The auto-planning scripts and documentation will be made freely available to other institutions and clinics.

2.
Pract Radiat Oncol ; 14(2): e165-e172, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38048988

RESUMO

PURPOSE: The purpose of this work is to develop a method to automate the treatment planning process of craniospinal irradiation (CSI) using volumetric modulated arc therapy. METHODS AND MATERIALS: Two scripts were developed using the Eclipse Scripting Application Programming Interface to perform auto-plan preparation and optimization. Ten patients (age, 5-44 years) previously treated at our institution with low dose volumetric modulated arc therapy CSI (prescription of 12 Gy) before total body irradiation were selected to evaluate the efficacy of the proposed auto-planning process. Paired t tests compared the dosimetric indices of the auto-plans to the manually generated clinical plans. All plans were normalized to 95% of planning target volume (PTV) coverage with the prescription dose. Two physicians and one physicist were asked to evaluate the manual plans and auto-plans of each patient in a blinded retrospective review and to indicate clinical acceptability and which plans were preferred for treatment. RESULTS: Compared with the manual CSI plans, the auto plans obtained significant reductions in Dmean to the parotids, submandibular glands, larynx, thyroid, and significant reduction in the plan PTV Dmax and D0.03 cc. The standard deviation range of the dosimetric parameters was greatly reduced for auto plans (range, 0.1-1.3 Gy) relative to manual plans (range, 0.4-5.9 Gy) indicating better plan consistency. Among the 10 patients, the auto-plans were preferred over the manual plans 90% of the time by the reviewing experts. The required time for auto-planning was approximately 1 hour compared with estimated 4 or more hours for manual planning. CONCLUSIONS: Reductions in planning time without sacrifices in plan quality were obtained using the auto-planning process compared with manual planning. Variation in plan quality was also reduced. The auto-planning scripts will be made freely available to other institutions and clinics.


Assuntos
Radiação Cranioespinal , Médicos , Radioterapia de Intensidade Modulada , Humanos , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Instalações de Saúde , Glândula Parótida
3.
ArXiv ; 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36866227

RESUMO

There is increasing recognition that oral health affects overall health and systemic diseases. Nonetheless it remains challenging to rapidly screen patient biopsies for signs of inflammation or the pathogens or foreign materials that elicit the immune response. This is especially true in conditions such as foreign body gingivitis (FBG), where the foreign particles are often difficult to detect. Our long term goal is to establish a method to determine if the inflammation of the gingival tissue is due to the presence of a metal oxide, with emphasis on elements that were previously reported in FBG biopsies, such as silicon dioxide, silica, and titanium dioxide whose persistent presence can be carcinogenic. In this paper, we proposed to use multiple energy X-ray projection imaging to detect and to differentiate different metal oxide particles embedded inside gingival tissues. To simulate the performance of the imaging system, we have used GATE simulation software to mimic the proposed system and to obtain images with different systematic parameters. The simulated parameters include the X-ray tube anode metal, the X-ray spectra bandwidth, the X-ray focal spot size, the X-ray photon number, and the X-ray dector pixel. We have also applied the de-noising algorithm to obtain better Contrast-to-noise ratio (CNR). Our results indicate that it is feasible to detect metal particles as small as 0.5 micrometer in diameter when we use a Chromium anode target with an energy bandwidth of 5 keV, an X-ray photon number of 10^8, and an X-ray detector with a pixel size of 0.5 micrometer and 100 by 100 pixels. We have also found that different metal particles could be differentiated from the CNR at four different X-ray anodes and spectra. These encouraging initial results will guide our future imaging system design.

4.
J Xray Sci Technol ; 30(4): 667-675, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35466921

RESUMO

BACKGROUND: X-ray image quality relies heavily on the emitted X-ray photon number which depends on X-ray tube current and exposure time. To accurately estimate the absorbed dose in an imaging protocol, it is better to simulate the X-ray imaging with a Monte Carlo platform such as GATE (Geant4 Application for Tomographic Emission). Although input of GATE is the X-ray photon number of the simulated X-ray tube, it lacks a good way to setup the photon number for a desired X-ray tube current setting. OBJECTIVE: To provide a method to correlate the experimental X-ray tube current exposure time and the X-ray photon number in GATE. METHODS: The accumulated radiation dose of a micro-computed tomography (CT) X-ray tube was recorded at different current exposure times with a general-purpose ion chamber. GATE was used to model the experimental microCT imaging system and calculate the total absorbed dose (cGy) in the sensitive volume of the ion chamber with different X-ray photon numbers. Linear regression models are used to establish a correlation between the estimated X-ray photon number and the X-ray tube settings. At first, one model establishes the relationship between the experimentally measured dose and the X-ray tube setting. Then, another model establishes a relationship between the simulated dose and the X-ray number in GATE. At last, by correlating these two models, a regression model to estimate the X-ray output number from an experimental X-ray tube setting (mAs) is obtained. RESULTS: For a typical micro-CT scan, the X-ray tube is operated at 50 kVp and 0.5 mA for a 500 ms exposure time per projection (0.25 mAs). For these X-ray imaging parameters, the X-ray number per projection is estimated to be 3.613×106 with 1.0 mm Al filter. CONCLUSION: The findings of this work provide an approach to correlate the experimental X-ray tube current exposure time to the X-ray photon number in the GATE simulation of the X-ray tube to more accurately determine radiation dose for an imaging protocol.


Assuntos
Doses de Radiação , Método de Monte Carlo , Imagens de Fantasmas , Microtomografia por Raio-X , Raios X
5.
J Xray Sci Technol ; 29(5): 867-880, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34275923

RESUMO

BACKGROUND: The time of flight (TOF) cone beam computed tomography (CBCT) was recently shown to reduce the X-ray scattering effects by 95% and improve the image CNR by 110% for large volume objects. The advancements in X-ray sources like in compact Free Electron Lasers (FEL) and advancements in detector technology show potential for the TOF method to be feasible in CBCT when imaging large objects. OBJECTIVE: To investigate the feasibility and efficacy of TOF CBCT in imaging smaller objects with different targets such as bones and tumors embedded inside the background. METHODS: The TOF method used in this work was verified using a 24 cm phantom. Then, the GATE software was used to simulate the CBCT imaging of an 8 cm diameter cylindrical water phantom with two bone targets using a modeled 20 keV quasi-energetic FEL source and various TOF resolutions ranging from 1 to 1000 ps. An inhomogeneous breast phantom of similar size with tumor targets was also imaged using the same system setup. RESULTS: The same results were obtained in the 24 cm phantom, which validated the applied CBCT simulation approach. For the case of 8 cm cylindrical phantom and bone target, a TOF resolution of 10 ps improved the image contrast-to-noise ratio (CNR) by 57% and reduced the scatter-to-primary ratio (SPR) by 8.63. For the case of breast phantom and tumor target, image CNR was enhanced by 12% and SPR was reduced by 1.35 at 5 ps temporal resolution. CONCLUSIONS: This study indicates that a TOF resolution below 10 ps is required to observe notable enhancements in the image quality and scatter reduction for small objects around 8 cm in diameter. The strong scattering targets such as bone can result in substantial improvements by using TOF CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Imagens de Fantasmas , Espalhamento de Radiação
6.
J Xray Sci Technol ; 29(5): 773-784, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34151883

RESUMO

BACKGROUND: Pencil beam X-ray luminescence computed tomography (XLCT) imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries. However, the pencil beam geometry suffers from long scan times, resulting in concerns overdose which discourages the use of pencil beam XLCT. OBJECTIVE: The dose deposited in pencil beam XLCT imaging was investigated to estimate the dose from one angular projection scan with three different X-ray sources. The dose deposited in a typical small animal XLCT imaging was investigated. METHODS: A Monte Carlo simulation platform, GATE (Geant4 Application for Tomographic Emission) was used to estimate the dose from one angular projection scan of a mouse leg model with three different X-ray sources. Dose estimations from a six angular projection scan by three different X-ray source energies were performed in GATE on a mouse trunk model composed of muscle, spine bone, and a tumor. RESULTS: With the Sigray source, the bone marrow of mouse leg was estimated to have a radiation dose of 44 mGy for a typical XLCT imaging with six angular projections, a scan step size of 100 micrometers, and 106 X-ray photons per linear scan. With the Sigray X-ray source and the typical XLCT scanning parameters, we estimated the dose of spine bone, muscle tissues, and tumor structures of the mouse trunk were 38.49 mGy, 15.07 mGy, and 16.87 mGy, respectively. CONCLUSION: Our results indicate that an X-ray benchtop source (like the X-ray source from Sigray Inc.) with high brilliance and quasi-monochromatic properties can reduce dose concerns with the pencil beam geometry. Findings of this work can be applicable to other imaging modalities like X-ray fluorescence computed tomography if the imaging protocol consists of the pencil beam geometry.


Assuntos
Processamento de Imagem Assistida por Computador , Luminescência , Algoritmos , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Raios X
7.
J Magn Reson Imaging ; 50(4): 1227-1237, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30843311

RESUMO

BACKGROUND: Magnetization transfer saturation (MTsat ) derives a semiquantitative index of magnetization transfer in faster acquisition times than quantitative magnetization transfer; the potential of MTsat for muscle imaging has not yet been explored. PURPOSE: To evaluate the potential of MTsat to identify regional and sex differences in calf muscle. STUDY TYPE: Prospective cohort study. PHANTOM/SUBJECTS: Vials with different agar and nickel nitrate concentrations providing a range of macromolecular fraction and T1 . Seven male subjects (25 ± 7 years) and seven female subjects (28 ± 14 years); three subjects were scanned in three separate sessions to assess reproducibility. FIELD STRENGTH/SEQUENCE: 3T, 3D fast low angle shot (FLASH) sequence with and without a magnetization transfer pulse; acquisition time of 4.12 minutes. ASSESSMENT: The effectiveness of two methods of fat suppression was evaluated using the fat unsuppressed sequence as the reference and MTsat maps derived with and without transmit field inhomogeneity corrections were compared. Statistical evaluation of MTsat differences between calf muscles and between male and female cohorts was made. STATISTICAL TESTS: Bland-Altman plots were used to assess fat suppression and B1+ correction. The coefficient of variation (CV) and the repeatability coefficient (RC) were calculated from the repeat sessions. Sex and regional differences were assessed using two-way factorial analyses of variance (ANOVAs) with Bonferroni-adjusted independent sample t-tests for post-hoc analyses. RESULTS: In phantoms, MTsat increased linearly with agar concentration and MTsat was independent of T1 (P = 0.229) evaluated in phantoms with two T1 s. The CV and RC of MTsat ranged between 2.65 to 5.03% and 0.13 to 0.38, respectively, in the different calf muscles. MTsat of the tibialis anterior was significantly higher than other muscles (P < 0.05). MTsat in male subjects was significantly higher than in female subjects (P = 0.009). DATA CONCLUSION: MTsat maps of calf muscle acquired under 5 minutes may have the potential to detect regional and sex differences. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1227-1237.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Adulto , Estudos de Coortes , Feminino , Humanos , Perna (Membro)/anatomia & histologia , Imãs , Masculino , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores Sexuais
8.
Biomed Opt Express ; 10(1): 372-383, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30775106

RESUMO

X-ray luminescence computed tomography (XLCT) has the potential to image the biodistribution of nanoparticles inside deep tissues. In XLCT, X-ray excitable nanophosphors emit optical photons for tomographic imaging. The lifetime of the nanophosphor signal, rather than its intensity, could be used to extract biological microenvironment information such as oxygenation in deep tumors. In this study, we propose the design, the forward model, and the reconstruction algorithm of a time domain XLCT for lifetime imaging with high spatial resolution. We have investigated the feasibility of the proposed design with numerical simulations. We found that the reconstructed lifetime images are robust to noise levels up to 5% and to unknown optical properties up to 4 times of absorption and scattering coefficients.